Digital, optical, calibration free – dissolved oxygen senors for the IQ SENSOR NET
Calibration-free, reliable, DIN compliant – the optical FDO® oxygen sensors for the IQ SENSOR NET to regulate biological cleaning steps:
• Calibration and flow free
• Insensitive to air bubbles
• Low usage costs
FDO® sensors are the perfect solution for measuring dissolved oxygen. In addition to being free of calibration and flow, with their 45° membrane, they are also insensitive to air bubbles. Therefore, you will not require any additional installation equipment. The robust design of this sensors allows the use with an overpressure of up to 10 bar. The special membrane has a unique stability and thus ensures stable measured values.
The sea water model (FDO® 700 IQ SW) is optimized for use in special media: All wetted parts are made of titanium and plastic and are therefore extremely resistant to corrosion.
| Modele | FDO® 700 IQ | FDO® 700 IQ SW* | FDO® 701 IQ | FDO® 701 IQ SW* |
| Order No. | 201650 | 201652 | 201660 | 201653 |
| Measuring method | optical | |||
| Replacement caps | SC-FDO® 700 working life of 2 years |
SC-FDO® 701 working life of 6 months |
||
| Measuring range (25 °C): O2 concentrationO2 saturation |
0 … 20,00 mg/l (0 … 20,00 ppm) 0 … 200,0 % |
|||
| Accuracy | < 1 mg/l (ppm): ± 0,05 mg/l (ppm) > 1mg/l (ppm): ± 0,1 mg/l (ppm) |
|||
| Response time at 25 °C | t90: < 150 s t95: < 200 s |
t90: < 60 s t95: < 80 s |
||
| Temp. measurement | Integrated NTC, 23 °F … 140 °F (-5 °C … +60 °C) ± 0.5 °C | |||
| Ambient Conditions | -5 °C … +50 °C -25 °C … +50 °C |
-5 °C … +40 °C -25 °C … +40 °C |
||
| Electrical connections | 2-wire shield cable with quick fastener to sensor | |||
| Weight (without cable) | Ca. 900 g | Ca. 1.500 g | Ca. 900 g | Ca. 1.500 g |
| * SW: Sensor as sea water model (with plastic arming (POM)) | ||||

In contrast to the standard BOD5 method the BioMonitor measures the total BOD. Measurement range: 1-200.000 mg/l BOD, 0 100 % Toxicity, Respiration in mg O2/l x min

NitraVis 700 IQ NI: Sensor with maintenance-free ultrasonic cleaning for measurement of nitrate and nitrite directly in the process – optimized for municipal wastewater treatment systems

UV 700 IQ NOx: Low-cost probe with integrated ultrasonic cleaning for the maintenance-free and reagent-free measurement of nitrate

On-line analyzer for the continuous measurement of Total Organic Carbon (TOC) in pure and ultrapure water.