Digital IQ sensor for wastewater treatment plants, connectable to the IQ SENSOR NET

TetraCon® 700 IQ – digital 4 electrode conductivity measuring cell with flow-free operation, especially with high conductivity:
• Very large measuring range from 10 µS/cm … 500 mS/cm
• Highest linearity and very insensitive against contamination by 4-electrode system
• Rapid temperature compensation by integrated temperature sensor
This measuring technique has proven itself over the years and offers an interference-free operation, also and foremost at high conductivity values. The 4-electrode measuring cell is very insensitive to contamination. Based on the pressure resistance of up to 10 bars, there is nothing to stop you from mounting into pipes or on lines.

The sea water model includes the sensor for use in special media: All wetted parts are made of titanium and plastic and are therefore extremely resistant to corrosion.

Model TetraCon® 700 IQ TetraCon® 700 IQ SW*
Order No. 302500 302501
Measuring method 4-electrode cell
Measuring range 10 µS/cm – 500 mS/cm
SAL: 0 … 70
TDS: 0 … 2000 mg/l
Cell Constants K = 0.917 cm-1, ±1.5% (in free solution)
K = 0.933 cm-1, TetraCon® 700 IQ with EBST 700-DU/N flow-thru adapter
K = 0.917 cm-1, ±1.5% (in free solution)
Resolution Depending on measuring range
Temp. measurement -5 … +60 °C (23 … 140 °F); NTC
Ambient Conditions -5 … +60 °C (23 … 140 °F)
Electrical connections 2-wire shield cable with quick fastener to sensor
Weight (without cable) Approx. 1.46 lb (660 g) Approx. 2.58 lb (1,170 g)
* SW: Sensor as sea water model (with plastic arming (POM))

Related Products

Color Sensors For Wastewater And Surface Water

Color sensors for wastewater and surface water

Spectral UV-VIS sensor to measure color in wastewater, incl. integrated ultrasonic cleaning; available wavelengths (selectable): 340 nm, 350 nm, 390 nm, 410 nm, 445 nm, 455 nm, 465 nm; including turbidity compensation

Biomonitor

LAR BOD Analyzer : BioMonitor

In contrast to the standard BOD5 method the BioMonitor measures the total BOD. Measurement range: 1-200.000 mg/l BOD, 0 100 % Toxicity, Respiration in mg O2/l x min

Chlorine Analyzer 3017m

chlorine analyzer 3017M

photometric analyzer with large measuring range and a high resolution for free and total chlorine with the DPD method according to the ISO and US EPA.

Iq Sensor Net Controller 281

IQ SENSOR NET Controller 281

Universal monitor DIQ/S 281-CR2. The new system 281 – the digital and cost-efficient single parameter measuring point with proven IQ Sensor Net technology and IQ sensors for the standard parameters.

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy