LAR BOD Analyzer : ToxAlarm
LAR’s toxicity analyzer ToxAlarm™ continually monitors drinking and surface water for pollutants. Potential toxins in water are determined through the reaction of highly sensitive bacteria.
Digital, optical, calibration free – dissolved oxygen senors for the IQ SENSOR NET
Calibration-free, reliable, DIN compliant – the optical FDO® oxygen sensors for the IQ SENSOR NET to regulate biological cleaning steps:
• Calibration and flow free
• Insensitive to air bubbles
• Low usage costs
FDO® sensors are the perfect solution for measuring dissolved oxygen. In addition to being free of calibration and flow, with their 45° membrane, they are also insensitive to air bubbles. Therefore, you will not require any additional installation equipment. The robust design of this sensors allows the use with an overpressure of up to 10 bar. The special membrane has a unique stability and thus ensures stable measured values.
The sea water model (FDO® 700 IQ SW) is optimized for use in special media: All wetted parts are made of titanium and plastic and are therefore extremely resistant to corrosion.
| Modele | FDO® 700 IQ | FDO® 700 IQ SW* | FDO® 701 IQ | FDO® 701 IQ SW* |
| Order No. | 201650 | 201652 | 201660 | 201653 |
| Measuring method | optical | |||
| Replacement caps | SC-FDO® 700 working life of 2 years |
SC-FDO® 701 working life of 6 months |
||
| Measuring range (25 °C): O2 concentrationO2 saturation |
0 … 20,00 mg/l (0 … 20,00 ppm) 0 … 200,0 % |
|||
| Accuracy | < 1 mg/l (ppm): ± 0,05 mg/l (ppm) > 1mg/l (ppm): ± 0,1 mg/l (ppm) |
|||
| Response time at 25 °C | t90: < 150 s t95: < 200 s |
t90: < 60 s t95: < 80 s |
||
| Temp. measurement | Integrated NTC, 23 °F … 140 °F (-5 °C … +60 °C) ± 0.5 °C | |||
| Ambient Conditions | -5 °C … +50 °C -25 °C … +50 °C |
-5 °C … +40 °C -25 °C … +40 °C |
||
| Electrical connections | 2-wire shield cable with quick fastener to sensor | |||
| Weight (without cable) | Ca. 900 g | Ca. 1.500 g | Ca. 900 g | Ca. 1.500 g |
| * SW: Sensor as sea water model (with plastic arming (POM)) | ||||

LAR’s toxicity analyzer ToxAlarm™ continually monitors drinking and surface water for pollutants. Potential toxins in water are determined through the reaction of highly sensitive bacteria.

Standard-compliant turbidity measurement with ultrasonic cleaning, according to US EPA 180.1 and DIN EN ISO 7027.

ViSolid®: Optical sensors for the in-situ use to measure suspended solids via scattered light and direct back-scattering with ultrasonic cleaning system

LAR’s QuickTOCeco™ is an online analyzer for the Total Organic Carbon (TOC) in water and process water, as condensate return and cooling water. At 1,200°C