Drinking Water Panel

Thanks to the combination of our proven IQ Sensor Net system with the intelligent IDS sensors, the measuring panel delivers accurate and reliable results.

Pre-assembled drinking water panel for monitoring turbidity, pH, conductivity, redox, oxygen and free chlorine.

Each drinking water panel is equipped with piping, pressure reducer, valve, tapping valve, flow indicator and maintenance console.  The version of the measuring panel tailored to your needs also includes the necessary tubing and flow vessels.

Applications:

  • Drinking water
  • Industry
Sensor Measuring range Accuracy Resolution
FCML 412-M12-2 Cl 0.005 … 2.000 mg/l <1 % up to 16 mg/l 0.001 mg/l
FCML 412 M12-20 0.05 … 20.00 mg/l 0.01 mg/l
SenTix® 945 (-P) pH 0.000 … 14.000 pH pH: ±0.004; (IDS measurement electronics)
U [mV]: ±0.2;
T [°C]: ±0.1
0.001 pH;
0.1 mV
SensoLyt® 900- ORP-P
ORP
-1250.0 … +1250.0 mV U [mV]: ±0.2
T [°C]: ±0.1
0.1 mV
TetraCon® 925 (-P) Cond ϰ: 0.0 µS/cm … 2000 mS/cm
SAL: 0.0 … 70.0
TDS: 0 mg/l … 199.9 g/l
±0.5 % from measured value;
T [°C]: ±0.1
ϰ: Up to 0.1 μS/cm
or until 0.01 mS/cm
SAL: 0.1
TDS: Up to 1 mg/l or until 0.01 g/l
LR 925/01(-P) 0.01 … 199.9 µS/cm ±0.5 % from measured value Up to 0.01 µS/cm
Turb PLUS 2000 Turb Factory setting: 0 … 100 NTU; optional: 0 … 10 und 0 … 1000 NTU Up to ±2 % of the measured value
or ±0.02 NTU
Up to 0.0001 NTU
FDO® 925(-P) O2
at 20 °C (68 °F)
0.00 … 20.00 mg/l
0.0 … 200.0 %
±1.5 % 0.01 mg/l
0.1 %
Panel /Measuring system
Outputs Relais:
Power outputs:
Digital:
Number selectable
(mA) Number selectable
Profinet, Profibus, Modbus RTU, Modbus TCP, Ethernet/IP
Data logger Data memory for up to 525,600 data sets
USB interface Included as standard on all panels

Related Products

Turb 2000 Turbidity Meter

TURB 2000 Turbidity meter

Standard-compliant turbidity measurement with ultrasonic cleaning, according to US EPA 180.1 and DIN EN ISO 7027

Quickcod Lab

LAR COD Analyzer : QuickCOD lab

LAR’s QuickTOCultra continually checks the TOC content of waste water. Optionally, other sum parameters can be detected aswell. At 1,200 °C,msamples are completely oxidised and within 3 minutes the TRUE TOC result is determined.

Quicktoc Trace

LAR TOC Analyzer : QuickTOC trace

For the continuous online determination of the total organic carbon (TOC) in ultra pure water applications. Measuring range 0.1 to 1,000 ppb TOC

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy