IQ conductivity measuring cell

Digital IQ sensor for wastewater treatment plants, connectable to the IQ SENSOR NET

TetraCon® 700 IQ – digital 4 electrode conductivity measuring cell with flow-free operation, especially with high conductivity:
• Very large measuring range from 10 µS/cm … 500 mS/cm
• Highest linearity and very insensitive against contamination by 4-electrode system
• Rapid temperature compensation by integrated temperature sensor
This measuring technique has proven itself over the years and offers an interference-free operation, also and foremost at high conductivity values. The 4-electrode measuring cell is very insensitive to contamination. Based on the pressure resistance of up to 10 bars, there is nothing to stop you from mounting into pipes or on lines.

The sea water model includes the sensor for use in special media: All wetted parts are made of titanium and plastic and are therefore extremely resistant to corrosion.

Model TetraCon® 700 IQ TetraCon® 700 IQ SW*
Order No. 302500 302501
Measuring method 4-electrode cell
Measuring range 10 µS/cm – 500 mS/cm
SAL: 0 … 70
TDS: 0 … 2000 mg/l
Cell Constants K = 0.917 cm-1, ±1.5% (in free solution)
K = 0.933 cm-1, TetraCon® 700 IQ with EBST 700-DU/N flow-thru adapter
K = 0.917 cm-1, ±1.5% (in free solution)
Resolution Depending on measuring range
Temp. measurement -5 … +60 °C (23 … 140 °F); NTC
Ambient Conditions -5 … +60 °C (23 … 140 °F)
Electrical connections 2-wire shield cable with quick fastener to sensor
Weight (without cable) Approx. 1.46 lb (660 g) Approx. 2.58 lb (1,170 g)
* SW: Sensor as sea water model (with plastic arming (POM))

Related Products

Monitor Ami Linetoc Ac

Monitor AMI LineTOC AC

On-line analyzer for the continuous measurement of Total Organic Carbon (TOC) in pure and ultrapure water.

Uv701 705 Sensors For Sac And Uvt

UV701/705 sensors for SAC and UVT

UV 700 IQ SAC: Low-cost probe (integrated ultrasonic cleaning, turbidity compensation) for the maintenance-free and reagent-free SAC measurement according to DIN 38404 C3

Color Sensors For Wastewater And Surface Water

Color sensors for wastewater and surface water

Spectral UV-VIS sensor to measure color in wastewater, incl. integrated ultrasonic cleaning; available wavelengths (selectable): 340 nm, 350 nm, 390 nm, 410 nm, 445 nm, 455 nm, 465 nm; including turbidity compensation

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy