• Washing unit and sterilization tunnel for vials and cartridges supplied in bulk.
• Denesting unit for RTU (Ready-to-use) formats.
• 100% checkweighing.
• Gas flushing before, during or after the filling process.
• Dosing system for CIP / SIP conditions.
• Automatic rejection of defective containers.
• SCADA software to process data acquisition in accor-dance with FDA 21CFR Part 11.
• Monitoring and particle counting.
• Laminar flow / RABS / Isolator.
• IQ / OQ validation package.

Model VSC/1 VSC/2 VSC/4 VSC/6 VSC/8
Output max. 3,600 uph 7,200 uph 12,000 uph 18,000 uph 24,000 uph
Container sizes Ø 40 – h 140 mm max.

Related Products

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy