SOLAR RADIATION (Global Irradiance) Second Class Pyranometers

Surface temperature
Surface contact temperature Robust sensor for outdoor application even in severe environmental conditions
SOLAR RADIATION (Global Irradiance) Second Class Pyranometers
Radiometer for solar irradiance measurement, according to Second class as ISO 9060 and WMO No. 8 standards.
This sensor is a good compromise for basic meteorological, agrometeorological and solar energy applications.
• Spectrally flat Class C (Second Class) pyranometer. Compliance with IEC 61724-1: 2017
• Electrical insulated (DPA863-873), Galvanic insulated (DPA983)
• Calibration traceability to WRR
• Modbus register for Instant value, Ave/Min/Max values over programmable time base (DPA983)
• Ideal instrument in PV plants performance monitoring and meteorological networks
| PN | DPA053A | DPA863 | DPA983 |
![]() |
![]() |
![]() |
|
| Output | µV | 4…20 mA | RS485-Modbus |
| Protocol | – | – | Modbus RTU®, TTY-ASCII |
| Programmable output | – | – | Ist., max/min/ave. (1…3600 s) |
| RS485 protection | – | – | Galvanic insulation (3 kV, UL1577) |
| RS485 speed | – | – | 1200…115 kbps |
| Power supply | – | 10…30 Vac/dc | 10…30 Vac/dc |
| Power consumption | – | 0.5 W | 0.5 W |
| EMC | – | EN 61326-1: 2013 | EN 61326-1: 2013 |
| Thermopile ensitivity | 10…15 µV/W/m2 | NA | NA |
| Measuring range | See Irradiance range | 0…1500 W/m2 | 0…1500 W/m2 |
| Impedance | 40 ± 3 Ω | – | – |
| Calibration certificate | Included | Not included (see Accessories) |
Not included (see Accessories) |
| Cable | L= 5 m included | Not included (see Accessories) |
Not included (see Accessories) |
| Built-in bubble level | NO (Yes, using DYA048 plate) | YES | YES |
| Mounting | • DYA032 arm + DYA049 collar (horizontal) • DYA048 plate + DYA035 arm + DYA049 collar |
DYA034 (horizontal) or DYA035 (tilting) arms + DYA049 collar |
|
| Data logger compatibility |
• M-Log (ELO008) • Alpha-Log (usingALIEM module) • E-Log |
• M-Log (ELO008) • Alpha-Log (usingALIEM module) • E-Log |
• M-Log (ELO008) using RS485->232 converter • Alpha-Log • E-Log (using RS485->232 converter) |

Surface contact temperature Robust sensor for outdoor application even in severe environmental conditions

Accurate temperature measurements (0.1°C) , 4-wires technologiy for long distance sensor cable

compact size and high mechanical strength, these sensors are particularly suited for use in strong wind applications.

Wind direction sensor with analog signal output. All models use a Hall effect encoding system.