Second Class Pyranometers

SOLAR RADIATION (Global Irradiance) Second Class Pyranometers

Radiometer for solar irradiance measurement, according to Second class as ISO 9060 and WMO No. 8 standards.
This sensor is a good compromise for basic meteorological, agrometeorological and solar energy applications.

• Spectrally flat Class C (Second Class) pyranometer. Compliance with IEC 61724-1: 2017
• Electrical insulated (DPA863-873), Galvanic insulated (DPA983)
• Calibration traceability to WRR
• Modbus register for Instant value, Ave/Min/Max values over programmable time base (DPA983)
• Ideal instrument in PV plants performance monitoring and meteorological networks

PN DPA053A DPA863 DPA983
Dpa053a Dpa863 Dpa983
Output µV 4…20 mA RS485-Modbus
Protocol – – Modbus RTU®, TTY-ASCII
Programmable output – – Ist., max/min/ave.
(1…3600 s)
RS485 protection – – Galvanic insulation
(3 kV, UL1577)
RS485 speed – – 1200…115 kbps
Power supply – 10…30 Vac/dc 10…30 Vac/dc
Power consumption – 0.5 W 0.5 W
EMC – EN 61326-1: 2013 EN 61326-1: 2013
Thermopile ensitivity 10…15 µV/W/m2 NA NA
Measuring range See Irradiance range 0…1500 W/m2 0…1500 W/m2
Impedance 40 ± 3 Ω – –
Calibration certificate Included Not included
(see Accessories)
Not included
(see Accessories)
Cable L= 5 m included Not included
(see Accessories)
Not included
(see Accessories)
Built-in bubble level NO (Yes, using DYA048 plate) YES YES
Mounting • DYA032 arm + DYA049
collar (horizontal)
• DYA048 plate + DYA035
arm + DYA049 collar
DYA034 (horizontal)
or DYA035 (tilting) arms
+ DYA049 collar
Data logger
compatibility
• M-Log (ELO008)
• Alpha-Log (usingALIEM module)
• E-Log
• M-Log (ELO008)
• Alpha-Log (usingALIEM module)
• E-Log
• M-Log (ELO008) using
RS485->232 converter
• Alpha-Log
• E-Log (using RS485->232 converter)

Related Products

Lsi Alpha Log 01

Alpha-Log

Alpha-Log is the most powerful data logger in the LSI Lastem family. With 400MB of internal memory and the removable memory up to 32GB it is suitable also in complex systems

Lsi Secondary Standard Pyranometers 01

Secondary Standard Pyranometers

These sensors are classified as ISO 9060 Secondary Standard. With a total daily uncertainty of only 2% within 0…180° field of view, fast response time,

Lsi Rainfall 01

Rainfall

A Rain gauge Design made in compliance to WMO ,Class A (UNI EN 17277:2020) accuracy over intensity(see PN)

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy