Second Class Pyranometers
Radiometer for solar irradiance measurement, according to Second class as ISO 9060 and WMO No. 8 standards. This sensor is a good compromise for basic
The data logger for meteorological monitoring
E-log has been explicitly designed for environmental applications: it is equipped with specific inputs for a wide range of sensors and calculations of derived quantities. E-Log stores the data from the connected sensors and supports different communcation protocols both in input and output. Robust and reliable, E-Log makes measurements possible even in the most severe environments, while the 16-bit A/D converter ensures accurate and reliable data in classic meteorological, hydrological and air quality applications and – more generally – in any environmental application.
• N. 8/16 analog inputs, n.4 digital inputs,;
I• nput extension using MASTER/SLAVE configurations;
• Extremely low power consumption;
• N. 99 measurements between channels for sensor acquisition and derived quantities;
• Internal library for calculating derived quantities and mathematical calculations;
• 8MB Flash Memory;
• Modbus-RTU Master/Slave, TTY protocols;
• Model with Zig-Bee 2,4 GHz Radio for radio sensor reception and from other modules (ELO3515)
• Transmission (push) of data in ASCII format with FTP protocols;
• N. 2 RS232 ports (ELO3305);
• N. 1 RS232 port and N. 1 RS485 port (ELO3305.1);
• Digital outputs to implement external devices with programmable logics or events;
• Acquisition rate from 1 s to 12 hours;
• Elaboration rate from 1 s to 12 hours;
• Connection to the PC via RS232 (USB/Ethernet/Modem GPRS with external accessories);
• Display and keyboard.
| Code | ELO3305 | ELO3515 | ELO3305.1 | |
![]() |
||||
| Description | E-Log data logger. N.12 inputs by terminal block | |||
| Inputs type | Terminal block | |||
| Analog inputs | N.8 differential (N. 16 single-ended) | |||
| Digital inputs | N.4 (on/off or frequency/counter) | |||
| Serial Ports | N.2 RS232 | N.1 RS232 N.1 RS485 |
||
| • Type: ZigBee • Frequency: ISM 2.4 GHz direct sequence channels • Power:10 mW (+10 dBm) |
||||
| Sensor’s auto-recognition | NO | |||
| On/off outputs | YES | |||
| Back-lit display | NO | |||
| Threaded slot for tripod fixing | NO | |||
| Internal battery | NO | |||
| Plug for power battery charger | YES | |||
| Included accessories | RS232/USB adapter, RS232 cable, DIN-bar mounting | RS232/USB adapter, RS232 cable, DIN-bar mounting, adapter for RS485 cable wires |
||
| Analog inputs | Range | Resolution | Accuracy (@ 25°C) |
|
| Volt | -300…1200 mV | 40 µV | ±100 µV | |
| ±78 mV | 3 µV | ±35 µV | ||
| ±39 mV | 1.5 µV | ±25 µV | ||
| Pt100 | 50…125°C | 0.003°C | ±0.05°C | |
| -50…600°C | 0.013°C | ±0.11°C | ||
| Resistances | 80…140 Ω | 0.0013 Ω | ±0.02 Ω | |
| 80…320 Ω | 0.005 Ω | ±0.05 Ω | ||
| 0…6000 Ω | 0.19 Ω | ±1.5 Ω | ||
| Thermo-couples | E-IPTS 68 -200…1000°C | <0.1°C | ±1.5°C | |
| J-IPTS 68 -50…600°C | <0.1°C | ±1.2°C | ||
| J – DIN -50 … 600°C | <0.1°C | ±1.2°C | ||
| K-IPTS 68 -150…1350°C | <0.1°C | ±1.9°C | ||
| S-IPTS 68 0…1600°C | 0.22°C | ±4.9°C | ||
| T-IPTS 68 -200…200°C | <0.1°C | ±1.4°C | ||
| Inputs number | N.8 differential (N.16 single-ended) | |||
| Voltage clamping | ±2.5 V | |||
| ESD protections (complies standards) |
IEC 61000-4-2 Contact Discharge ±12 kV IEC 61000-4-2 Air-Gap Discharge ±15 kV IEC 61000-4-5 Surge 3.0 A (8/20 µs) |
|||
| EMC filter | X2Y filters on all inputs | |||
| Channel to Channel crosstalk |
-80 dB | |||
| Temperature error (@-10…30°C) |
300…1200 mV < ±0,01% FS ±39 mV < ±0.01% FS ±78 mV < ±0.01% FS |
|||
| Digital inputs | Inputs number | N.4 | ||
| Mode | • N.2 input for sensors with optoelectronics (freq. max 10 kHz) • N.2 Frequency input (freq. max 5 kHz) • N.4 Logic state input ON/OFF (they acquire signals 0 … 3 Vdc) |
|||
| Max input freq. | 5 kHz | |||
| Accuracy | 3 Hz @ 5 kHz | |||
| Protections (power) |
Peak pulse power: • 600 W (10/1000 μs) • 4 kW (8/20 μs) |
|||
| Protections (complies standards) |
IEC 61000-4-2 level 4: • 15 kV (air discharge) • 8 kV (contact discharge) IEC 61000-4-5 MIL STD 883G, method 3015-7: class 3B • 25 kV HBM (human body model) |
|||
| Switched power supply outputs |
Number | N.7 (with programmable switching-on time before sensor acquisition) | ||
| Max total current | On a single output: 1.1 A Total for all outputs: 7.7 A |
|||
| Voltage clamping | +33 V | |||
| Protections | On each output: PTC overcurrent protections (resettable) max 1.1 A | |||
| Protections (power) | Peak pulse power: • 600 W (10/1000 μs) • 4 kW (8/20 μs) |
|||
| Protections (complies standards) |
IEC 61000-4-2 level 4: • 15 kV (air discharge) • 8 kV (contact discharge): IEC 61000-4-5 MIL STD 883G, method 3015-7: class 3B • 25 kV HBM (human body model) |
|||
| RS-232-485 ports | Number/type PN:MDMMB1110 |
N.2 RS-232 ports (N.1 for system setup and data display by PC, N.1 for Modbus-RTU output) |
||
| Number/type PN:MDMMB1110.1 |
N.1 RS-232 for system setup and data display by PC N.1 RS-485 for Modbus-RTU output (with isolated 12V@160 mA) |
|||
| Speed | 1200…115200 bps | |||
| Type | Db-9 pin/male/female/DCE | |||
| Voltage clamping | ±15 V | |||
| Protections (power) | Peak pulse power: • 600 W (10/1000 μs) • 4 kW (8/20 μs) |
|||
| Protections (complies standards) |
IEC 61000-4-2 level 4: • 15 kV (air discharge) • 8 kV (contact discharge): IEC 61000-4-5 MIL STD 883G, method 3015-7: class 3B • 25 kV HBM (human body model) |
|||
| Others | Standard | EN 61326-1 2013 , EN 61010-1 2013, EN 50581 2013 | ||
| Watch | Accuracy: 30 s/month (@ 25°C) | |||
| Keyboard | N.4 keys | |||
| Processor | 2 RISC 8 bit, clock 16 MHz | |||
| A/D converter | 18 bit resolution (rounded to 16 bit) | |||
| Sample duration | (rejection 50/60 Hz): 80 ms@rejection 50 Hz | |||
| Data memory | Flash EEPROM 8 Mb | |||
| Environm.limits | -30…70°C, 15…100 % RH (without water condensation) | |||
| Physical protection |
Conformal coating on the electronic board to protect the board’s components against moisture, dust, chemicals, and temperature extremes | |||
| Protection grade | IP 40 | |||
| Weight | 720 g | |||
| Dimensions | 242 x 108 x 80 mm | |||

Radiometer for solar irradiance measurement, according to Second class as ISO 9060 and WMO No. 8 standards. This sensor is a good compromise for basic

N. 8/16 analog inputs , n.4 digital inputs,Input extension using MASTER/SLAVE configurations , Extremely low power consumption

Air temperature and relative humidity Temperature measurement principle RTD Pt100 1/3 DIN B (Class AA EN60751) and capacitive humidity.

Ultrasonic anemometer. Highlights. Wide range of signal outputs 4-20 mA, RS232/485 Modbus;; No moving parts;; Very-High speed wind measurement (0-85 m/s)