• Pressure measuring range: 50 mbar … 1000 bar
• Accuracy: ≤ ± 0.10 / 0.05 % FS
• Operating temperature: -40 … 125°C
• Process temperature: -40 … 150°C
• Output signal: 4 … 20 mA
• Total Error Band: ≤ ± 0.15 %FS (0 … 70°C)
• Materials: Stainless steel, Titanium

benefits
• Certificates: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
• Any measuring ranges between 0 … 50 mbar and 0 … 1000 bar available
• Static accuracies available to 0.05 %FS
• Hysteresis and repeatability better than 0.01 %
• Piezoresistive technology suitable for static and dynamic pressure measurements
• Modular design ideal for customization to the application
• Barometric or negative pressure ranges available

Pressure Measuring Range (Bar)
0 … 0.05 to 0 … < 0.1 0 … 0.1 to 0 … < 1 0 … 1 to 0 … ≤ 100
Overpressure 3 bar 3 bar 3 x FS
Burst pressure > 200 bar > 200 bar > 200 bar
Accuracy, (3) (± % FS) ≤ 0.25 ≤ 0.2 / ≤ 0.1 ≤ 0.2 / ≤ 0.1 / ≤ 0.05
Total Error, (4), (5) (± % FS ; typ. / max.)
0 … 70°C compensated ≤ 0.4 / 0.6 ≤ 0.2 / 0.4 ≤ 0.15 / 0.3
-25 … 100°C compensated ≤ 0.5 / 0.7 ≤ 0.3 / 0.5 ≤ 0.2 / 0.4
-40 … 125°C compensated ≤ 0.7 / 1.0 ≤ 0.4 / 0.7 ≤ 0.3 / 0.6
Response time, (typ.) < 1ms / 10 … 90 % FS < 1ms / 10 … 90 % FS < 1ms / 10 … 90 % FS
Long term stability,
(typ./max. per year)
< 1 mbar / < 2 mbar < 1 mbar / < 2 mbar < 0.1% FS / < 0.2% FS
0 … > 100 to 0 … ≤ 600, (2) 0 … > 600 to 0 … 1000 0.8 … 1.2, (1)
Overpressure 3 x FS (≤ 850 / ≤ 1500 bar) ≤ 850 / ≤ 1500 bar 3 x FS
Burst pressure > 850 / > 1500 bar > 850 / > 1500 bar > 200 bar
Accuracy, (3) (± % FS) ≤ 0.2 / ≤ 0.1 ≤ 0.2 ≤ 0.2 / ≤ 0.1
Total Error, (4), (5) (± % FS ; typ. / max.)
0 … 70°C compensated ≤ 0.3 / 0.5 ≤ 0.4 / 0.6 ≤ 0.2 / 0.4
-25 … 100°C compensated ≤ 0.5 / 0.7 ≤ 0.7 / 1.0 ≤ 0.3 / 0.5
-40 … 125°C compensated ≤ 0.7 / 0.9 ≤ 1.0 / 1.2 ≤ 0.4 / 0.7
Response time, (typ.) < 1ms / 10 … 90 % FS < 1ms / 10 … 90 % FS < 1ms / 10 … 90 % FS
Long term stability,
(typ./max. per year)
< 0.1% FS / < 0.2% FS < 0.1% FS / < 0.2% FS < 1 mbar / < 2 mbar
-0.025…0.025 to -0.1…0.1 >-0.1… >0.1 to -0.5…0.5 >-0.5… >0.5 to -1…100
Overpressure 3 bar 3 bar 3 bar / 3 x FS
Burst pressure > 200 bar > 200 bar > 200 bar
Accuracy, (3) (± % FS) ≤ 0.25 ≤ 0.2 / ≤ 0.1 ≤ 0.2 / ≤ 0.1
Total Error, (4), (5) (± % FS ; typ. / max.)
0 … 70°C compensated ≤ 0.4 / 0.6 ≤ 0.2 / 0.4 ≤ 0.15 / 0.3
-25 … 100°C compensated ≤ 0.5 / 0.7 ≤ 0.3 / 0.5 ≤ 0.2 / 0.4
-40 … 125°C compensated ≤ 0.7 / 1.0 ≤ 0.4 / 0.7 ≤ 0.3 / 0.6
Response time, (typ.) < 1ms / 10 … 90 % FS < 1ms / 10 … 90 % FS < 1ms / 10 … 90 % FS
Long term stability,
(typ./max. per year)
< 1 mbar / < 2 mbar < 1 mbar / < 2 mbar < 0.1% FS / < 0.2% FS

Related Products

L Series With Rs232

Galltec L Series with RS232 / RS485

Economical transmitters of the L Series are primarily optimized for ambient room conditions and are very well suited to help control energy costs in HVAC and building automation applications.

L Series With Analogue Outputs

Galltec L Series with analogue outputs

Economical transmitters of the L Series are primarily optimized for ambient room conditions and are very well suited to help control energy costs in HVAC and building automation applications.

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy