DARA – Pilot freeze dryers
Ready for scale up
• Washing unit and sterilization tunnel for vials supplied in bulk.
• 100% checkweighing.
• Gas flushing before, during or after the filling process.
• Dosing system for CIP / SIP conditions.
• Vacuum-assisted insertion of stoppers to reduce the presence of oxygen in headspace.
• Automatic rejection of defective vials.
• SCADA software to process data acquisition in accor-dance with FDA 21CFR Part 11.
• Monitoring and particle counting.
• Laminar flow / RABS / Isolator.
• IQ / OQ validation package.
| Model | SX-310-PP/S | SX-310-PP/MF/S | SX-310-PP/D | SX-310-PP/MF/D |
| Output max. | 3,600 uph | 7,200 uph | ||
| Containers sizes | Ø 52 – h 110 mm max. | Ø 36 – h 75 mm max. | ||

Ready for scale up

Filling from 0.1 ÷ 250 ml / Dosing accuracy ±0.2% / Drip-free function / Automatic recalibration / Easy and quick maintenance / Output up to 6,000 uph

Injection stretch blow moulding and filling line for plastic bottles or bags

No cross contamination / Filling from 0.1 ÷ 1,050 ml / Flow up to 6.4 l/min / Dosing accuracy ±0.5% / Product changeover in 1 minute / Drip-free function / Automatic recalibration / Audit trail