PCME STACK 181 : Particulate Measurement System

US EPA PS11 compliant ProScatter™ particulate CEM providing high quality emission measurement for low dust concentrations from industrial processes

• Continuous Particulate Monitoring for saturated wet stack applications typically found after wet FGDs or filtration systems that produce a wet/condensing flue gas (wet ESPs/scrubbers)
• US EPA PS11 capable as a PM–CPMS or PM–CEMS
• Extractive sampling system configurable for fixed velocity or isokinetic variable flow rate sampling
• Heated sample lines to maintain sample temperature and prevent the formation of condensation
• Forward Scatter measurement technique with automatic zero and span (upscale) checks that fully challenge the system to satisfy daily drift check requirements
• Easy to use intuitive multi-lingual text driven menu and display for improved user interface complete with on-board data logging for increased level of security of data
• Small sample chamber and use of advanced polymers – prevents particulate adhesion, condensation and crystal formation. Reduced maintenance for the end user

Measurement capability 0 – 500 mg/m(for higher concentrations, please consult ENVEA)
Detection Limit < 0.1 mg/m3
Probe Variants Probe lengths 600mm,
1200mm (other lengths available on
request)PVDV (standard) corrosion resistant Stainless Steel: non-corrosive stacks Hastelloy corrosion resistant
Stack Temperature Ranges up to 200°C
Functionality and QA Checks Automatic self-checks (zero and span)
QA data logging
Data Output RS485 (Modbus) RS232 (Modbus) Ethernet
Measured parameters Dust
Technology Extractive ProScatter™ Forward Scatter
Measurement/Monitoring capability 0-500 mg/m³*
Stack/Duct diameter suitability up to 15m
Flue gas temperature up to 200°C
Baghouse
Cartridge Filter
Ceramic Filter
Coalescent Filter
Cyclone
Electrostatic Precipitator (ESP)
Wet Electrostatic Precipitator YES
Wet Scrubber YES
Sensor variants PVDF corrosion resistant
Stainless Steel
Hastelloy®
QA checks YES
*Application dependant

Stacks with saturated wet flue gas, typically after wet flue gas desulphurisation plant, wet collectors, etc
Typical Applications:
• Power Generation Plant eg Coal/Biomass
• Incineration
• Metals eg Steel/Aluminium
• Minerals eg Cement/Gypsum
• Chemicals eg Detergent / Carbon Black
• Fertiliser
• Pulp and Paper

Related Products

Infralyt 80

Infralyt 80

The INFRALYT 80 is a customer specific configurable gas analyzer for applications at industry and laboratory. It measures up to 8 gases at once, special

Psg Basic Extruded 01

PSG Basic Extruded

Description. The controlled heated sample lines of the PSG Extruded basic series are used for the continuous analysis of extractive gases.

The Laser Diode Gas Analyzer Lds 6

The laser diode gas analyzer LDS6

The in-situ gas analyzer LDS 6 is characterized by a high availability and unique analytical selectivity and is optimally suitable for numerous applications.

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy