SOLAR RADIATION (Global Irradiance) Secondary Standard Pyranometers

Wet temperature
Accurate temperature measurements (0.1°C) , 4-wires technologiy for long distance sensor cable
SOLAR RADIATION (Global Irradiance) Secondary Standard Pyranometers
Radiometer for solar irradiance measurement, according to ISO 9060 and WMO No. 8 (Part I, Chapter 7) standards. These sensors are classified as ISO 9060 Secondary Standard. With a total daily uncertainty of only 2% within 0…180° field of view, fast response time, these sensors are ideal for users requiring high-end accuracy and reliability
• Spectrally flat Class A (Secondary Standard) pyranometer. Compliance with IEC 61724-1: 2017
• RVH technology: Recirculating Ventilation and Heating (DPA953.1)
• Measured sensor tilt angle (DPA953.1)
• Calibration traceability to WRR
• Outputs: irradiance in W/m², instrument body temperature , tiltangle, internal humidity, internal pressure and ventilator speed (DPA953.1)
• Ideal instrument in PV plants performance monitoring and meteorological networks
| PN | DPA252 | DPA952 | DPA953.1 |
![]() |
![]() |
![]() |
|
| Output | µV | RS485-Modbus 4…20 mA |
RS485-Modbus |
| Ventilation | Not included (Yes, using DPA250) |
Not included (Yes, using DPA250) |
Included |
| Heater | Yes (5 V) | ||
| Tilt measurement | – | – | YES (Acc± 1°) |
| Power supply | – | 7…35 Vdc | 8…30 Vdc |
| Power consumption | – | < 75 x 10-3 W@12 VDC | < 3 W@12 VDC |
| Thermopile sensitivity | 7…25 µV/W/m2 | NA | NA |
| Irradiance range | 0…4000 W/m2 | RS485: -400…4000 W/m2 4…20 mA: 0…1500 W/m2 |
-400…4000 W/m2 |
| Impedance | 40 ± 3 Ω | – | – |
| Response time | 4.5 s | 4.5 s | 3 s |
| Output values | Instant value | Running average value over 4 measurements, refreshed every 0.1 s |
Running average value over 4 measurements, refreshed every 0.1 s |
| Cable | Not included (see Accessories) |
Not included (see Accessories) |
Not included (see Accessories) |
| Output | Irradiance in W/m2 | • Irradiance in W/m2 • Sensor body temperature (digital output only) |
• Irradiance in W/m2 • Sensor body temperature • Sensor internal RH% • Sensor internal Pressure in Pa • Instrument tilt angle • Ventilator speed in RPM • Ventilator current in A • Heater current in A |
| Data logger compatibility |
• M-Log (ELO008) • Alpha-Log (using ALIEM module) • E-Log |
Using 4…20 mA output: • M-Log (ELO008) • Alpha-Log (using ALIEM module) • E-Log |
• M-Log (ELO008) using RS485->232 converter • Alpha-Log • E-Log (using RS485->232 converter) |

Accurate temperature measurements (0.1°C) , 4-wires technologiy for long distance sensor cable

A Rain gauge Design made in compliance to WMO ,Class A (UNI EN 17277:2020) accuracy over intensity(see PN)

KME Weather Stations KME Weather Stations are professional and economical complete solutions for obtaining the

LSI Lastem has a wide range of models to cover any need for meteorological … First Class pyranometers. Pyranometers with 5% total daily accuracy (ISO9060)