The OXY-Flex Oxygen Analyzer is suitable for measuring in oxygen closed systems

Gas Analysis Probe (GAP)
the GAP provides customers with a single gas flue or ventilation monitoring control system
The OXY-Flex Oxygen Analyzer is suitable for measuring in oxygen closed systems
The OXY-Flex Oxygen Analyzer is suitable for measuring in oxygen closed systems, such as ventilation pipes and boiler exhaust flues.
The OXY-Flex Oxygen Analyzer is designed to measure the oxygen concentration in air or gas mixtures with temperatures of -100 to 400⁰C. The oxygen analyzer employs a well proven, small zirconium dioxide based element at its heart and due to its innovative design does not require a reference gas. The oxygen sensor element is mounted in the tip of the stainless steel probe and is protected by a sintered stainless steel cap.
The OXY-Flex Oxygen Analyzer uses a unique closed loop measurement system. While the sensor continuously measures the oxygen level, a heartbeat signal is also generated providing an immediate warning of any failures.
The OXY-Flex can be configured to output measuring ranges of 0-25% O₂ or 0-100% O₂. The entire measurement range is linear in both cases. The outputs can be configured to either 4-20mA and 0-10Vdc outputs or an RS232 serial communications interface.
Typical applications include; combustion control of industrial boilers, burning oil, gas, coal or biomass; incubators; composting probes and welding equipment.
FEATURES
– Zirconium dioxide technology
– High accuracy linear output
– Configurable outputs; 4-20mA and 0-10Vdc or RS232 comms interface
– Selectable output measuring ranges; 0-25% O₂ or 0-100% O₂ or fully adjustable via RS232
– Can be calibrated in fresh air (20.7% O₂) or in any other known O₂ concentration
– Housed in a sealed die-cast aluminium housing with attached oxygen sensor probe and amphenol Ecomate connector
– Works at temperatures from -100 to 400⁰C
– Various probe lengths available
BENEFITS
– Long life, non-depleting technology
– No reference gas required creating the ability to measure a wide oxygen range
– Removes the need for customers to implement their own electronics
– No need for temperature stabilisation
– Linear output signal
– Externally triggered automatic or manual single point calibration removing any effect of barometric pressure
– Can be used in high pressure and temperature environments
– No need for external heater supply
– Full technical and application support available

the GAP provides customers with a single gas flue or ventilation monitoring control system

OXITEC® 5000 The best sensor for measurement of O2, which is just as reliable and robust in reducing atmospheres, thanks to integrated Cell Surface Protection.

Being able to withstand high flue gas temperatures up to 600°C and high dust loads

The COMTEC® 6000 is an InSitu analyzer for measurement of O2 and COe (sum of unburned molecules – CO, H2, CxHy) in flue and process gases.