AccuFlo® Zero

Allows automatic and demand orientated zero point calibration of DP flow transmitters

  • Technical GasesFlow measurement solutions for Technical Gases
  • Compressed AirFlow measurement solutions for Compressed Air
  • Exhaust AirFlow measurement solutions for Exhaust Air
  • Fresh and Combustion AirFlow measurement solutions for Fresh and Combustion Air
  • Steam/Heat QuantitiesFlow measurement solutions for Steam/Heat Quantities
  • Heat Transfer FluidsFlow measurement solutions for Heat Transfer Fluids
  • WaterFlow measurement solutions for Water
  • Exhaust GasCertified Emission Flow Monitoring for Exhaust Gases

Most flow measurements are not regularly subject to maintenance after installation and commissioning. System with averaging pitot tubes, orifice plates and other DP flow elements utilize DP flow transmitters. These electronic devices are subject to changes in ambient temperature, operating pressure and long term drift. All factors can lead to considerable measurement errors particularly at smaller measured differential pressure values. These errors are typically only noticed during phases of plant shutdowns or at worst remain completely undected. In almost all cases the problem could be solved with a demand-oriented zero calibration of the DP transmitter.

This is exactly where the patented AccuFlo® Zero comes into play. It performs this important maintenance work – the zero point calibration – automatically whenever it is necessary. It is an ideal accessory for all differential pressure pressure based flow measurements.

Since the AccuFlo® Zero basically eliminates the residual zero point error of DP transmitter it increases total measurement range through a large increase in total accuracy at lower rates.

The AccuFlo® Zero is also easy to retrofit in existing installations and works with almost all makes of DP transmitters.

The AccuFlo® Zero offers practical advantage wherever

  • The maintenance efforts for DP flow measurement system should be reduced and automated,
  • Demand-oriented execution zero point calibration should be guaranteed,
  • Error at small measured DP values have led to problems in the past
  • Dynamic range and accuracy shall be increased without replacing the measurement
  • Costs should be saved,
  • Installation of a second differential pressure transmitter (split range system) has not yielded the desired success.
Zero point calibration: based on change of ambient temperature (interval adjustable, standard: 5 Kelvin)
based on change of operating pressure (interval adjustable, standard: 5 bar, absolute pressure has to be measured inside DP transmitter)
based on long term drift (interval adjustable, standard: 24 h)
Duration of cailbration ca. 30 s
Last measured value: Held constant during calibration
Ambient temperatuer −20 … 55 °C
Pressure rating: PN 100
Wetted Parts: 1.4571 (AISI 316Ti)
Supply voltage: 24 V DC
Installation Usually between DP transmitter and existing manifold

Related Products

Sdf Sensors For Steam 01

SDF-Sensors for Steam

Averaging Pitot Tubes for accurate flow measurement of saturated and superheated steam for low, middle and high pressure applications.

Accuflo® Lpd 01

AccuFlo® LPD

Mass flow meter with certified accuracy for accurate measurement of gases, liquids and steam.

Accumind®

AccuMind®

Universal flow and energy computer for liquids, gases, and steam with capacitve touch screen display and various interfaces.

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy