The VN2000 Hot Tap Insertion Vortex Flow Meter measures the flow of steam, gas or liquids over a large flow range. The meter is a heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe.
The vortex sensing element is CNC machined out of one piece of solid stainless steel. The dual ceramic piezoelectric sensors are bonded inside the vortex element, which is press-fit to the stainless steel insertion bar and completely welded together. There are no internal O-rings or seals of any kind and absolutely no leak paths into the sensors or electronics. Our sensors do not touch the process fluid, which gives them an almost unlimited life span.
ideal for accurately measuring liquids, compressed air and saturated steam. No moving parts and virtually maintenance-free once installed.
• Removable Insertion/Extraction Tool. Aids in installation or removal in high pressure applications
• Reliable measurement for steam and a variety of fluids. Heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe
• Reduced Maintenance Costs and Spare Parts. No internal o-rings or seals of any kind and absolutely no leak paths into the sensors or electronics. Our sensors do not touch the process fluid, which gives them an almost unlimited life span.
Volumetric Flow |
±1.0% of reading (for Liquids, Gas & Steam) |
Repeatability |
±0.25% of reading (for Liquids, Gas & Steam) |
Mass or Heat Flow |
±1.0% of reading (for Liquids, Gas & Steam) |
Velocity – Liquid |
1.32…32 ft/s |
Velocity – Gas |
cube root (140/ρ) ft/s… 300 ft/sec (91 m/sec) |
Reynolds Range |
10,000…7,000,000 depending on fluid density |
Straight Run Pipe |
Upstream 10 diameters; downstream 5 diameters with one 90° elbow before the meter |
Pipe sizes |
2…36 in. |
Fluid temperature |
–250…400° F |
Maximum Pressure |
Up to 1,000 psi |
Wetted Materials |
Stainless steel 304L |
Hot Tap Connections |
1-1/2 in: NPT, ASME/ANSI 150, 300 flanges Sealing assembly: Two ethylene propylene O-rings Optional removable extractor |
• Measure volume or Btu of liquids
• Measure volumetric or mass flow rate of steam or gas
• Standardize on an insertion bar that can measure line sizes 2…36 in.
• Reduced noise interference with dual piezoelectric sensors and filtering
• Machined safety stop provides constant seal, will not leak
• Standard model handles process temperatures up to 400° F (204° C)
• Reduced maintenance due to:
– No moving parts
– Heavy duty welded stainless steel construction
– Piezoelectric and temperature sensors never touch process fluid
– No recalibration necessary
– No pins or screws to corrode and rust