NivuFlow 600 WS

Flow transmitter for drinking water applications
Transmitter for accurate flow measurement using the ultrasonic transit time difference method with non-contact clamp-on sensors. Especially for drinking water applications.

The NivuFlow 600 WS measurement system was specially developed for drinking water applications. Using the transit time difference method, we are setting new standards for the measurement and monitoring of drinking water flows.

Thanks to our clamp-on sensors, the process does not have to be interrupted. Operations can continue smoothly while the measurement is set up within a few minutes. We also guarantee absolute hygiene, as our sensors have no direct contact with drinking water.

With the NivuFlow 600 WS, not only the flow rate, but also the flow velocity and water temperature can be reliably measured, even at very low flow velocities of up to 3 cm/s. Structural modifications to the cross-section to generate higher flow velocities are therefore no longer necessary.

The compact enclosure for DIN rail mounting is suitable for space-saving installation in control cabinets. Special field enclosures are available for use in harsh environmental conditions. A large, easy-to-read daylight display enables the flow meter to be set up quickly and easily. It also offers extended diagnostic options for detailed analysis of running processes directly in the field.

Your Benefits

  • Easy installation without interrupting the supply, no need to cut the pipeline or flush the pipe
  • Absolute hygiene, as it does not come into contact with the medium
  • Easy commissioning thanks to menu-supported sensor alignment
  • Intuitive, modern operating concept for quick and easy commissioning and diagnostics on site
  • IP68 field enclosure available
  • IoT-ready with global 4G connection for maximum availability and digital services
  • IP68 Sensors
  • High measurement accuracies even at lowest flow velocities
  • Calculation of the water temperature based on the speed of sound
  • For all common pipe materials and pipe linings in the water industry
  • Direct installation in the ground, no shaft construction required
  • Monitoring of all system-relevant parameters (flow rate, flow velocity and temperature)
  • Bidirectional measurement possible

Typical Applications

  • Flow measurement in drinking water tanks, pumping stations, treatment plants, pressure boosting systems
  • Flow measurement in the drinking water network, buried applications
  • Hygiene monitoring in drinking water networks based on temperature
  • Flow measurement of springs
  • Transfer shafts between water suppliers
  • Control of flow rates (pumping stations, treatment plants)
Specifications
Number of paths 1
Communication
  • Modbus TCP via network (LAN/WAN, Internet)
  • Modbus RTU via RS485 or RS232
  • Ethernet TCP/IP
Data memory 1.0 GB internal memory, readout on faceplate via USB stick
Outputs
  • 1x (Type T2) 0/4-20 mA, load 500 Ohm, 12 Bit resolution
  • 1x (Type T2) relay SPDT, load up to 230 V AC/2 A (cos j 0.9), min. switching current 10 mA
Inputs
  • 1x (Type T2) 4-20 mA, with 12 Bit resolution for storage of data from external units, load 91 Ohm,
  • 1x (Type T2) digital input
Connection plug with spring cage terminal blocks
Operation rotary pushbutton, 2 function keys, menus in English, German, French, and others
Display 240 x 320 Pixel, 65536 colours
Max. humidity 80 %, non-condensing
Storage temperature −30 C to +80 °C
Operating temperature
  • DC: −20 °C to +70 °C
  • AC: −20 °C to +65 °C
Weight approx. 1150 g
Enclosure material: Aluminium, Plastic
Power consumption 1 relay energised, 230 V AC: (rounded) 14 W
Measurement range DN 50 – DN 800
Power supply 100 – 240 V AC, -15 % / +10 %, 47 to 63 Hz or 10 – 35 V DC

Related Products

Nivuflow 750 Flow Meter 01

NivuFlow 750 Flow Meter

For ultrasonic flow measurement of slight to heavily polluted media in part filled and full pipes and channels. Best possible results even under difficult conditions.

Ocm F Flow Meter 01

OCM F Flow Meter

For ultrasonic flow measurement of slight to heavily polluted media in part filled an full pipes and channels. Complete measurement system in connection with KDA sensors

Schmidt Flow Sensor Ss 20.651

SCHMIDT Flow Sensor SS 20.651

In many areas the measurement of the flow velocity and / or the volume flow at higher temperatures of up to +350 °C is very important in terms of energy efficiency, quantity detection and plant control.

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy