ECOMZEN your solution for indoor air quality monitoring
We spend more than 80% of our time indoors. However, indoor air can be up to eight times more contaminated than outdoor air.
An ally in your health, safety and environmental (HSE) program, EcomZen measures the following key indoor air quality parameters:
• Air pollutant concentrations: PM1, PM2,5, PM10, CO, CO2, VOC, H2S, SO2, NO2, O3, CH2O, HCl, Cl2. (available on request)
• Meteorological parameters: air temperature, air pressure and relative humidity
• Means of localization: GPS
EcomZen collects data in real time and wirelessly transmit them to Ecomesure’s advanced web platform, where they can be analyzed, managed and uploaded onto websites, smart building platforms, and imported into software. The web platform also allows you to remotely control your monitors.
BENEFITS
• All-in-one multi-parameter system
• Controlled calibration process for quality measurement
• Easy to install and use
• Centralized services on i-comesure.com
• Stand-alone version (solar panel & battery)
APPLICATIONS
• Urban centres, Smart cities
• Industrial sites (quarries, mines, airports, ports)
• Workshops, warehouses, work-sites
• Roads, tunnels, subway
| Dimensions/Weigh |
L8.2” x W7.8” x H3.5” / 4.41 lbs (2 kg) |
| Connectivity |
Ethernet |
| Options: Wi-Fi – 3G/4G/GPRS – LTE-M – LoRa – ZigBee Pro |
| Frequency |
One measurement every 60 seconds (ajustable from 10s to 1h) |
| Digital I/O |
1 Digital Input / 1 Digital Output |
| Localization |
Accelerometer, GPS |
| Data security |
Local + Cloud-based encryption |
| WPA2-Enterprise compatible |
| Data storage |
Built-in microSD memory card |
| Web storage |
| Power supply |
5 VDC USB, 2 A max. Adapter included: 100-240 VAC 50/60 Hz |
| IP67 power supply |
| Built-in battery backup (8h of use, 12h in LoRa) optional |
| “Autonomy kit” option |
Solar panel (55 W, 90 W, 115 W); Battery weather-resistant assembly |
| External fastening |
Clamped onto a post or a fence, weather-resistant (equivalent IP54) |
| Certifications |
CE Class B, FCC Class A |
| Patent |
Applicable in France, Europe, United States |
| Sensors |
Technology |
Range |
Detection limit |
| NO2 |
Electrochemical |
0-20 ppm |
< 0.02 ppm |
| O3 |
0-20 ppm |
< 0.02 ppm |
| CO |
0-50 ppm |
< 0.02 ppm |
| NO |
0-20 ppm |
< 0.08 ppm |
| SO2 |
0-50 ppm |
< 0.02 ppm |
| H2S |
0-50 ppm |
< 0.01 ppm |
| NH3 |
0-100 ppm |
< 3 ppm |
| HCHO |
0-10 ppm |
< 0.1 ppm |
| Cl2 |
0-20 ppm |
< 0.2 ppm |
| HCl |
0-20 ppm |
< 0.5 ppm |
| VOC50 and VOC3000 |
PID |
0-50 ppm | 0-3000 ppm |
1 ppb | 50 ppb |
| CO2 |
NDIR |
0-5000 ppm |
1 ppm |
| PM1, PM2,5 et PM10 |
Optical |
0-1000 μg/m³ |
1 μg/m3 |