STACKFLOW 400 : Flue Gas Velocity

Approved flue gas velocity CEM for stack velocity, volumetric flow and pollutant mass release calculations when linked to Gas and Dust CEMS

• Continuous superior measurement of flue gas velocity and temperature
• Inbuilt automatic reference self-checks for regulatory compliance (QAL3)
• Large measurement path (400mm) permits accurate and increased representative measurement
• Facilitates stack velocity, volumetric flow and pollutant mass release calculations when linked to gas and dust CEMS
• Angled probe version to fit existing perpendicular ports providing ease of installation

Measurement capability 0 – 50 m/s
Resolution 0.1 m/s
Sensor Variants 316 Stainless Steel
Stack Temperature Ranges -20°C – 200°C
Functionality and QA Checks Automatic reference checks
Data Output RS485 (Modbus) output to Controller
Enclosure Protection Rating IP65
Measured parameters Flue-gas velocity
Technology FlueSonic™ Ultrasonic
Measurement/Monitoring capability 0 – 50 m/s*
Stack/Duct diameter suitability up to 10m
Flue gas temperature up to 200°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter
Coalescent Filter YES
Cyclone YES
Electrostatic Precipitator (ESP) YES
Wet Electrostatic Precipitator YES
Wet Scrubber YES
QA checks YES
*Application dependant

Stack velocity, volumetric flow and pollutant mass release calculations (when linked to gas and dust CEMS)
Typical Applications:
• Incineration
• Metals (eg Steel/Aluminium)
• Minerals (eg Cement/Gypsum)
• Chemicals (eg Refinery / Rubber)
• Power Generation Plant (eg Coal/Biomass)

Related Products

รูปลงเว็บไซต์ (52)

Gas analyzer ULTRAMAT 23

The ULTRAMAT 23 is an innovative multi-component gas analyzer and can be equipped. precise and reliable analytical measurement devices that are affordable and easy-to-use

The Laser Diode Gas Analyzer Lds 6

The laser diode gas analyzer LDS6

The in-situ gas analyzer LDS 6 is characterized by a high availability and unique analytical selectivity and is optimally suitable for numerous applications.

Psg Basic Extruded 01

PSG Basic Extruded

Description. The controlled heated sample lines of the PSG Extruded basic series are used for the continuous analysis of extractive gases.

Psg Plus Cooler Mak 10 01

PSG Plus Cooler MAK 10

Compressor Cooler for CEMS (wash out optimized) with 1-4 Gas Path, Flow Rate up to 150 I/h and update optionsto full conditioing system

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy