Digital, optical sensor for the IQ SENSOR NET
NiCaVis® 700 IQ NI: UV probes with integrated ultrasonic cleaning for the reagent-free measurement of nitrate, nitrite and carbon parameters directly in the process:
• Measurement directly in the process
• No waiting for response times
• Maintenance-free WTW ultrasonic cleaning
• No wear parts, like wipers
• Now available for surface water
The full flexibility for your measurement:
The high resolution of these sensors allows the precise distinction and measurement of nitrate and nitrite. At the same time, up to 3 carbon parameter such as COD, BOD, DOC, TOC, UVT or SAC are determined. This allows the complete monitoring and optimization of processes in the aeration of wastewater treatment plants.
| Order No. |
481054 |
481055 |
| * The UVT-254 value is standardized to 10 mm gap width. |
| Measuring method |
Spectral Measurement in the UV Range (200 – 390 nm) |
Measuring gap
(optical layer thickness) |
1 mm |
5 mm |
| Application (optimized for) |
Municipal wastewater: |
Municipal wastewater: |
| Measuring range and Resolution |
|
Inlet: |
|
| NO3 |
0.0 … 300.0 mg/l 0.1 mg/l |
|
| NO3-N |
0.00 … 60.00 mg/l 0.01 mg/l |
|
| NO2 |
0.0 … 120.0 mg/l 0.1 mg/l |
|
| NO2-N |
0.00 … 30.00 mg/l 0.01 mg/l |
|
| COD total |
0 … 20,000 mg/l 1 mg/l |
|
| COD dissolv |
0 … 12,500 mg/l 1 mg/l |
|
| TOC |
0 … 20,000 mg/l 1 mg/l |
|
| DOC |
0 … 12,500 mg/l 1 mg/l |
|
| BOD |
0 … 8,000 mg/l 1 mg/l |
|
| SAC254 total |
0 … 5,000 1/m 1 1/m |
|
| UVT254 total* |
0 … 100.0 % 0.1 % |
|
|
Aeration: |
|
| NO3 |
0.0 … 300.0 mg/l 0.1 mg/l |
|
| NO3-N |
0.00 … 60.00 mg/l 0.01 mg/l |
|
| NO2 |
0.0 … 120.0 mg/l 0.1 mg/l |
|
| NO2-N |
0.00 … 30.00 mg/l 0.01 mg/l |
|
| COD dissolv |
0 … 12,500 mg/l 1 mg/l |
|
| DOC |
0 … 12,500 mg/l 1 mg/l |
|
| SAC254 total |
0 … 5,000 1/m 1 1/m |
|
| UVT254 total* |
0 … 100.0 % 0.1 % |
|
|
Effluent: |
Effluent: |
| NO3 |
0.0 … 750.0 mg/l 0.1 mg/l |
0.0 … 250.0 mg/l 0.1 mg/l |
| NO3-N |
0.0 … 150.0 mg/l 0.1 mg/l |
0.00 … 50.00 mg/l 0.01 mg/l |
| NO2 |
0.0 … 300.0 mg/l 0.1 mg/l |
0.0 … 100.0 mg/l 0.1 mg/l |
| NO2-N |
0.00 … 75.00 mg/l 0.01 mg/l |
0.00 … 25.00 mg/l 0.01 mg/l |
| COD total |
0 … 4.000 mg/l 1 mg/l |
0.0 … 800.0 mg/l 1 mg/l |
| COD dissolv |
0 … 4.000 mg/l 1 mg/l |
0.0 … 800.0 mg/l 1 mg/l |
| TOC |
0 … 2.500 mg/l 1 mg/l |
0.0 … 500.0 mg/l 1 mg/l |
| DOC |
0 … 2.500 mg/l 1 mg/l |
0.0 … 500.0 mg/l 1 mg/l |
| BOD |
0 … 2.500 mg/l 1 mg/l |
0.0 … 500.0 mg/l 1 mg/l |
| SAC254 total |
0 … 3.000 1/m 1 1/m |
0.0 … 600.0 1/m 1 1/m |
| UVT254 total* |
0 … 100.0 % 0.1 % |
0.0 … 100.0 % 0.1 % |
| Flow rate |
≤ 3 m/s |
| Pressure Resistance |
Maximum 1 bar (incl. sensor connection cable) |
| Electrical connections |
2-wire shield cable with quick fastener to sensor |
| Electromagnetic Compatibility |
EN 61326. Class B. FCC Class A
Intended for indispensable operation |
| Certifications |
CE |
| Mechanical |
Housing: Titan Grade 2. PEEK, Window: Sapphire glass
Protection class: IP 68 |
| Weight (without cable) |
Approx. 8.82 lb (4 kg) |