LAR’s COD analyzer QuickCODlab™ is the most reliable measurement system for the determination of the chemical oxygen demand in laboratories.

Using this environmentally friendly COD analyzer and analsis technique, you can now determine chemical oxygen demand quickly, cleanly and safely – without any chemicals.

Features and Benetits
• Measurement range: 100 – 1000 mg/l (depending on the application), 500 – 5,000 mg/l, 1000 – 8,000 mg/l, 22,000 – 250,000 mg/l, further options available
• Response time: 3 minutes
• Determination of the real oxygen demand
• Proven thermal temperature combustion
• Chemical-free technique
• Reliable measurement without reagents
• Excellent chloride acceptance

Applications
LAR’s total organic carbon analyzer is suitable for a variety of applications and types of water, even with frequently changing sample matrixes.
• Water Influent
• Water Effluent
• Discharge Control
• Industrial Waste Water
• De-Icing Water
• Process Water
• High Salt Concentrations
• Oil-in-Water

Measurement Technique and Sample Preparation
Measurement Method Thermal oxidation at 1,200 °C
Measurement Compliance According to DIN EN 1484:1997-08/ ISO 8245:1999-03/ US-EPA 415.1 / ASTM D-5173
Measurement Ranges 0.1 – 50,000 mg/l (ppm) TOC, with optional dilution up to 500,000 mg/l
(ppm) possible, other ranges on request
Parameter TOC, TC, TIC, combinations with COD, TNb possible
Sensitivity Depending on the detector/measuring range used for 0.1-100ppm –> 0.1ppm at 600µl injection volume
Oxidation Principle High Temperature Oxidation (Non-catalytic at 1,200 °C)
Accuracy Max. 2% of FSR
Repeatability Max. 2% of FSR
Cycle Time TConly / TNb / COD_o: 1-2 min.
TOCdiff: 4-5 min.
TOCdirect (NPOC): 4-6 min.
Response Time 3 minutes
Sample Preparation • Flow Sampler – Maintenance-free particle seperator
• Optional homogeniser for continuous homogenisation of samples
Particle Size Particles < 800µm
Temperature and Humidity
Permissible Sample Temperature 5-60°C / 41°F – 140°F TConly
5-50°C / 41°F – 122°F TOC
Ambient Temperature recommended 10 to 30 °C / 50°F – 86°F
Ambient Air Humidity Max. 80% (non condensing)
Dimensions and Weight
Housings Steel IP54, powder-coated; Optional: Stainless steel, IP 65, EXp Zone 1 and 2 for T3, T4 classes (ATEX, IECEx)
Dimensions W 848 x H 1100 x D 635 mm (Standard housing)
W 33.4″ x H 43.3″ x D 25″ (Standard housing)
Weight From 115 kg / 253.6Lbs (Standard housing)

Related Products

LAR TOC Analyzer : QuickTOC trace

For the continuous online determination of the total organic carbon (TOC) in ultra pure water applications. Measuring range 0.1 to 1,000 ppb TOC

LAR BOD Analyzer : NitriTox

LAR’s toxicity analyzer NitriTox™ continually monitors water treatment plants for pollutants. Potential toxins in water are determined through the reaction of highly sensitive bacteria.

LAR TNb Analyzer : QuickTONultra

LAR’s QuickTONultra continually monitors the TNb content of water. Optionally, further sum parameters can be detected, too. At 1,200 °C, samples are completely oxidised and only within 3 minutes the TNb result is determined.

UV sensors for nitrate

UV 700 IQ NOx: Low-cost probe with integrated ultrasonic cleaning for the maintenance-free and reagent-free measurement of nitrate

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy