Features
• Pressure measuring range: 100 mbar … 1000 bar
• Accuracy: ≤ ± 0.2 % FS
• Operating temperature: -40 … 125°C
• Process temperature: -40 … 150°C
• Output signal: 4 … 20 mA
• Total Error Band: ≤ ± 0.3 %FS (0 … 70°C)
• Materials: Stainless steel
benefits
• Certificates: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
• Any measuring ranges between 0 … 100 mbar und 0 … 1000 bar available
• Static accuracy available of 0.2 % FS
• Hysteresis and repeatability better than 0.01 % FS
• Piezoresistive technology suitable for static and dynamic pressure measurements
• Modular design ideal for customization to the application
• Barometric or negative pressure ranges available
| Pressure Measuring Range (Bar) |
|
0 … 0.1 to 0 … < 1 |
0 … 1 to 0 … ≤ 100 |
0 … > 100 to 0 … ≤ 600, (2) |
| Overpressure |
3 bar |
3 x FS |
3 x FS (≤ 850 / ≤ 1500 bar) |
| Burst pressure |
> 200 bar |
> 200 bar |
> 850 / > 1500 bar |
| Accuracy, (3) (± % FS) |
≤ 0.2 |
≤ 0.2 |
≤ 0.2 |
| Total Error, (4) (± % FS ; typ. / max.) |
| 0 … 70°C compensated |
≤ 0.4 / 0.8 |
≤ 0.3 / 0.6 |
≤ 0.7 / 1.0 |
| -25 … 100°C compensated |
≤ 0.6 / 1.0 |
≤ 0.4 / 0.8 |
≤ 1.0 / 1.2 |
| -40 … 125°C compensated |
≤ 0.8 / 1.4 |
≤ 0.6 / 1.2 |
≤ 1.0 / 1.5 |
| Response time, (typ.) |
< 1ms / 10 … 90 % FS |
< 1ms / 10 … 90 % FS |
< 1ms / 10 … 90 % FS |
Long term stability
(typ./max. per year) |
< 1 mbar / < 2 mbar |
< 0.1% FS / < 0.2% FS |
< 0.1% FS / < 0.2% FS |
|
0 … > 600 to 0 … 1000 |
0.8 … 1.2, (1) |
-0.05…0.05 to -0.1…0.1 |
| Overpressure |
≤ 850 / ≤ 1500 bar |
3 x FS |
3 bar |
| Burst pressure |
> 850 / > 1500 bar |
> 200 bar |
> 200 bar |
| Accuracy, (3) (± % FS) |
≤ 0.2 |
≤ 0.2 |
≤ 0.2 |
| Total Error, (4) (± % FS ; typ. / max.) |
| 0 … 70°C compensated |
≤ 0.7 / 1.0 |
≤ 0.4 / 0.8 |
≤ 0.4 / 0.8 |
| -25 … 100°C compensated |
≤ 1.0 / 1.2 |
≤ 0.6 / 1.0 |
≤ 0.6 / 1.0 |
| -40 … 125°C compensated |
≤ 1.0 / 1.5 |
≤ 0.8 / 1.4 |
≤ 0.8 / 1.4 |
| Response time, (typ.) |
< 1ms / 10 … 90 % FS |
< 1ms / 10 … 90 % FS |
< 1ms / 10 … 90 % FS |
Long term stability
(typ./max. per year) |
< 0.1% FS / < 0.2% FS |
< 1 mbar / < 2 mbar |
< 1 mbar / < 2 mbar |