IQ optical spectral probes (UV-VIS)
IQ optical spectral probes (UV-VIS) for carbon parameters and suspended solids
Optimal for the measurement of TOC and DOC in the inlet/effluent of municipal wastewater treatment plants.
Digital, optical sensor for the IQ Sesnor Net
NitraVis® 700 IQ NI: Sensor with maintenance-free ultrasonic cleaning for measurement of nitrate and nitrite directly in the process – optimized for municipal wastewater treatment systems:
• High measuring accuracy
• Easy handling
• Minimal operating costs
High measuring accuracy
The innovative spectral measuring technique of these sensors allows the determination of nitrate and nitrite directly in the process. Based on the measurement of the entire spectrum, cross sensitivities of individual parameters among each other and interference such as turbidty are eliminated effectively. This ensures highly precise and reliable measuring results!
Easy handling
Based on the optical method, time-consuming steps such as sampling and sample preparation are eliminated. This also eliminates waiting for response time, which allows for a nearly continuous measuring process. This makes measured values available quickly and without complications.
Minimal operating costs
Spare parts such as wiper profiles and seals are not necessary thanks to the maintenance-free ultrasonic cleaning. The use of a chemical-free measuring method further reduces operating costs to a minimum.
| Model | NitraVis® 701 IQ NI | NitraVis® 705 IQ NI | |
| Order No. | 481056 | 481057 | |
| Measuring method | Spectral Measurement in the UV Range (200 – 390 nm) | ||
| Measuring gap (optical layer thickness) |
1 mm | 5 mm | |
| Application (optimized for) | Municipal wastewater: | Municipal wastewater: | |
| Measuring range and Resolution | Inlet & Aeration: | ||
| NO3 | 0.0 … 300.0 mg/l 0.1 mg/l | ||
| NO3-N | 0.00 … 60.00 mg/l 0.01 mg/l | ||
| NO2 | 0.0 … 120.0 mg/l 0.1 mg/l | ||
| NO2-N | 0.00 … 30.00 mg/l 0.01 mg/l | ||
| Effluent: | Effluent: | ||
| NO3 | 0.0 … 750.0 mg/l 0.1 mg/l | 0.0 … 250.0 mg/l 0.1 mg/l | |
| NO3-N | 0.0 … 150.0 mg/l 0.1 mg/l | 0.00 … 50.00 mg/l 0.01 mg/l | |
| NO2 | 0.0 … 300.0 mg/l 0.1 mg/l | 0.0 … 100.0 mg/l 0.1 mg/l | |
| NO2-N | 0.00 … 75.00 mg/l 0.01 mg/l | 0.00 … 25.00 mg/l 0.01 mg/l | |
| Flow rate | ≤ 3 m/s | ||
| Pressure Resistance | Maximum 1 bar (incl. sensor connection cable) | ||
| Electrical connections | 2-wire shield cable with quick fastener to sensor | ||
| Electromagnetic Compatibility | EN 61326, Class B, FCC Class A Intended for indispensable operation |
||
| Certifications | CE | ||
| Mechanical | Housing: Titan Grade 2, PEEK Window: Sapphire glass Protection class: IP 68 |
||
| Weight (without cable) | Approx. 8.82 lb (4 kg) | ||
| Warranty | 2 years for defects in quality | ||

IQ optical spectral probes (UV-VIS) for carbon parameters and suspended solids
Optimal for the measurement of TOC and DOC in the inlet/effluent of municipal wastewater treatment plants.

Spectral UV-VIS sensor to measure color in wastewater, incl. integrated ultrasonic cleaning; available wavelengths (selectable): 340 nm, 350 nm, 390 nm, 410 nm, 445 nm, 455 nm, 465 nm; including turbidity compensation

The raw water sample is oxidized at 1,200 °C and the CO2 produced is deteced and quantitatively determined. High Temperature Method at 1,200 °C

LAR’s QuickTOCeco™ is an online analyzer for the Total Organic Carbon (TOC) in water and process water, as condensate return and cooling water. At 1,200°C