Electro-chemical IQ sensors for dissolved oxygen

Digital electro-chemical IQ sensors for dissolved oxygen, connectable to the IQ SENSOR NET

TriOxmatic® IQ: Reliable and proven digital electro-chemical oxygen sensors with 3 electrode system (ECDO) for precise and accurate measurements:
• Low investment costs
• No running in, no long-term drift – stable from the beginning to the end
• Self-diagnosis system SensReg/SensLeck by means of 3 electrode system
The electro-chemical sensors are known for their high accuracy – from the beginning. Their teflon membrane makes them extremely insensitive to biological deposits. Therefore, in most cases, you will not need an additional cleaning unit.

Also, the membrane – just like the electrolyte consumption – is monitored continuously. Our self-diagnosis system SensLeck and SensReg show occurring errors automatically.

The sea water model is optimized for the use in special media: All wetted parts consist of titanium and plastic and are therefore extremely corrosion-resistant.

Furthermore, if you want, you will find a sensor with a faster response time or for the measurement of trace oxygen.

Model TriOxmatic® 700 IQ TriOxmatic® 700 IQ SW* TriOxmatic® 701 IQ TriOxmatic® 702 IQ
Order No. 201640 201641 201644 201646
Measuring method Electrochemical
Measuring range (25 °C)
O2 concentration 0.0 … 60.0 mg/l 0.00 … 20.00 mg/l
0.0 … 60.0 mg/l
0 … 2000 µg/l
0.00 … 10.00 mg/l
O2 saturation 0 … 600% 0.0 … 200.0%
0 … 600%
0 … 110%
Resolution
O2 concentration 0.1 mg/l 0.01 mg/l
0.1 mg/l
0.001 mg/l
0.01 mg/l
O2 saturation 1% 0.1%
1%
0.1%
Response time at 25 °C t90: 180 s t90: 30 s
t99: 90 s
t90: 30 s
t99: 110 s
Minimum flow rate 0.05 m/s 0.23 m/s 0.3 m/s
SensCheck SensLeck
SensReg
SensReg SensLeck
SensReg

SensReg
Temp. measurement Integrated NTC, 23 °F … 140 °F (-5 °C … +60 °C) ± 0.5 °C
Temp. compensation 32 °F … 140 °F (0 °C … +60 °C)
Pressure Resistance 10 bar (incl. sensor connection cable)
Ambient Conditions Operating temperature: 32 °F … 140 °F (0 °C … +60 °C);
Storage temperature: 23 °F … 149 °F (-5 °C … +65 °C)
Electrical connections 2-wire shield cable with quick fastener to sensor
Electromagnetic Compatibility EN 61326, Class B, FCC Class A;
Intended for indispensable operation
Certifications CE, cETL, ETL
Mechanical Membrane head assembly, locking cap: POM
Sensor body: V4A stainless steel 1.4571
Protection rating: IP 68
Weight (without cable) Approx. 1.46 lb (660 g) Approx. 2.58 lb (1,170 g) Approx. 1.46 lb (660 g)
* SW: Sensor as sea water model (with plastic arming (POM))

Related Products

IQ optical spectral probes (UV-VIS)

IQ optical spectral probes (UV-VIS) for carbon parameters and suspended solids
Optimal for the measurement of TOC and DOC in the inlet/effluent of municipal wastewater treatment plants.

LAR COD Analyzer : QuickCOD lab

LAR’s QuickTOCultra continually checks the TOC content of waste water. Optionally, other sum parameters can be detected aswell. At 1,200 °C,msamples are completely oxidised and within 3 minutes the TRUE TOC result is determined.

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy