Features
• Pressure measuring range: 100 mbar … 1000 bar
• Accuracy: ≤ ± 0.2 % FS
• Operating temperature: -40 … 125°C
• Process temperature: -40 … 150°C
• Output signal: 4 … 20 mA
• Total Error Band: ≤ ± 0.3 %FS (0 … 70°C)
• Materials: Stainless steel

benefits
• Certificates: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
• Any measuring ranges between 0 … 100 mbar und 0 … 1000 bar available
• Static accuracy available of 0.2 % FS
• Hysteresis and repeatability better than 0.01 % FS
• Piezoresistive technology suitable for static and dynamic pressure measurements
• Modular design ideal for customization to the application
• Barometric or negative pressure ranges available

Pressure Measuring Range (Bar)
0 … 0.1 to 0 … < 1 0 … 1 to 0 … ≤ 100 0 … > 100 to 0 … ≤ 600, (2)
Overpressure 3 bar 3 x FS 3 x FS (≤ 850 / ≤ 1500 bar)
Burst pressure > 200 bar > 200 bar > 850 / > 1500 bar
Accuracy, (3) (± % FS) ≤ 0.2 ≤ 0.2 ≤ 0.2
Total Error, (4) (± % FS ; typ. / max.)
0 … 70°C compensated ≤ 0.4 / 0.8 ≤ 0.3 / 0.6 ≤ 0.7 / 1.0
-25 … 100°C compensated ≤ 0.6 / 1.0 ≤ 0.4 / 0.8 ≤ 1.0 / 1.2
-40 … 125°C compensated ≤ 0.8 / 1.4 ≤ 0.6 / 1.2 ≤ 1.0 / 1.5
Response time, (typ.) < 1ms / 10 … 90 % FS < 1ms / 10 … 90 % FS < 1ms / 10 … 90 % FS
Long term stability
(typ./max. per year)
< 1 mbar / < 2 mbar < 0.1% FS / < 0.2% FS < 0.1% FS / < 0.2% FS
0 … > 600 to 0 … 1000 0.8 … 1.2, (1) -0.05…0.05 to -0.1…0.1
Overpressure ≤ 850 / ≤ 1500 bar 3 x FS 3 bar
Burst pressure > 850 / > 1500 bar > 200 bar > 200 bar
Accuracy, (3) (± % FS) ≤ 0.2 ≤ 0.2 ≤ 0.2
Total Error, (4) (± % FS ; typ. / max.)
0 … 70°C compensated ≤ 0.7 / 1.0 ≤ 0.4 / 0.8 ≤ 0.4 / 0.8
-25 … 100°C compensated ≤ 1.0 / 1.2 ≤ 0.6 / 1.0 ≤ 0.6 / 1.0
-40 … 125°C compensated ≤ 1.0 / 1.5 ≤ 0.8 / 1.4 ≤ 0.8 / 1.4
Response time, (typ.) < 1ms / 10 … 90 % FS < 1ms / 10 … 90 % FS < 1ms / 10 … 90 % FS
Long term stability
(typ./max. per year)
< 0.1% FS / < 0.2% FS < 1 mbar / < 2 mbar < 1 mbar / < 2 mbar

Related Products

ATM/Ex – Analog Pressure Transmitter

Fast customization thanks to configurable product design. Pressure measuring range: 100 mbar … 1000 bar, Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS, Operating temperature: -25 … 85°C

Galltec L Series with RS232 / RS485

Economical transmitters of the L Series are primarily optimized for ambient room conditions and are very well suited to help control energy costs in HVAC and building automation applications.

Contact Us
By submitting this form with you information, you are indecating of our informal acceptance of our Privacy Policy