SDF-Sensors: Averaging pitot tubes for gases and liquids
For accurate flow measurement of gases and liquids

AccuFlo® Zero
Fully automatic, demand driven zero point calibration of differential pressure based flow measurements.
SDF-Sensors: Averaging pitot tubes for gases and liquids
For accurate flow measurement of gases and liquids
SDF-Sensors use the averaging pitot tube technology and are commonly used where flow rates of gases or liquids are measured. They have been proven in the field to be reliable, stable and accurate for more than 35 years.
Due to the robust technology and the simple principle of measurement, averaging pitot tubes can be used for difficult conditions and offer considerable advantages over other measuring technology from easy installation to long-term measuring stability.
Additional unique advantages are the possibilities of bidirectional flow measurement as well as the integration of temperature and pressure measurement.
With the FASTLOK version, the SDF-Sensor can be inserted or retracted without interrupting plant operation. They are available in four different versions for different pressure ratings and for hazardous gases or atmospheres. The FASTLOK probes can be equipped with a gas-tight packing gland assembly for hazardous fluids and with an integral gear drive for easy insertion/retraction.
SDF-Sensors offer practical advantages wherever
| Measured quantity: | Differential pressure Optional: Static pressure, Temperature |
| Measured Fluid: | Gases (with dust, water saturated, corrosive) Liquids (low viscosity) |
| Temperature range: | Standard: −50 … 450 °C, optional −180 … 1100 °C |
| Pressure range: | up to PN 320 (flanged) / ANSI #2500 upon request: welded design |
| Diameter range: | DN 25 up to 10000 mm 1″ up to 400″ (suitable for rectangular ducts) |
| Required inlet and outlet pipe straight runs: | 7xD inlet, 3xD outlet |
| Material: | Standard: 1.4404 / AISI 316L Other Options: 1.4541 (AISI 321), 1.4571 (AISI 316Ti), Hastelloy C22 (alloy 22), other materials upon request |
| Error limit k-factor: | ±1% of measured value |
| Reproducibility: | ±0,1 % of measured value |
| Measurement range: | up to 1:40 (in relation to max. flow) |

Fully automatic, demand driven zero point calibration of differential pressure based flow measurements.

Mass flow meter with certified accuracy for accurate measurement of gases, liquids and steam.

QAL1 and MCerts certified volume flow measurement for exhaust gas applications.

Air purging unit for reliable and safe cleaning of measurement ports of differential pressure flow sensors in gas applications with high dust load.