| Code |
DLALB0100 |
| Description |
Alpha-Log data logger |
| Inputs type |
Terminal block |
| Analog inputs |
N.1 0…2 Vdc input |
| Digital inputs |
N.2 pulse inputs |
| RS232 ports |
N.2 |
| USB ports |
N.2 |
| RS485 port |
N.1 |
| SDI-12 port |
N.1 |
Integrated Absolute
Pressure sensor |
YES |
Integrated
Temperature sensor |
YES |
| On/off outputs |
YES |
| Backlit display |
YES |
| Internal battery |
NO |
| Included accessories |
Ethernet cable, DIN-bar mounting |
| Alpha-Log (DLALB0100)—Technical Features |
Inputs ALIEM module
(MDMMB1110,
MDMMB1110.1) |
See MW9008-ENG-05-ALIEM data sheet |
Pulse input / frequency
(selectable) |
Inputs number |
N.2 |
| Features |
• N.2 single relay reeds from two rain gauges
• One rain gauge with double reed relay system
• N.2 frequency inputs from two optoelectronic anemometers
• N.1 relay reed from one rain gauge and N:1 frequency input from optoelectronic anemometer |
| Power supply |
Limited to 1 mA per reed relay |
| Input type |
Open collector with 3,3 V pullup resistance (positive input) |
Max input
frequency |
480 KHz (reed relay input)
10 KHz (frequency input) |
Rainfall
linearization |
Yes (using correction formula for Class A rain gauges according to UNI EN 17277:2020 ) |
| Protection |
• From reed relay rebounds
• From over-tension (> 5V)
• 400 W peak pulse power capability at 10/1000 us waveform.
Repetition rate (duty cycle): 0,01 %
• IEC-61000-4-2 ESD 30 kV (air), 30 kV (contact)
• ESD protection of data lines in accordance with IEC 61000-4-2
• EFT protection of data lines in accordance with IEC 61000-4-4 |
| Input (Temperature RH%) |
Input |
UART-TTL (DMA672.1 sensor), (DMA672.4 sensor when ELUxxx box is used) |
| Range |
• Temperature: -40…70°C
• RH%: 0…100%
• DewPoint: -40…70°C |
| Resolution |
• Temperature: 0,1°C
• RH%: 0…100%
• Dew Point: 0,1°C |
| Input Pt100 (Temperature sensor) |
Input |
Pt100 (3 wires) |
| Range |
-40…70°C |
| Resolution |
0.1°C |
| Accuracy |
±0.25 °C |
| Input Voltage |
Range |
0…2 V |
| Resolution |
12 bit |
| Accuracy |
1.8 mV |
| Dropping resistors |
100 ohm (N.1 included to convert 4…20 mA -> 200…1000 mV) |
| Internal Measurement (Absolute Pressure) |
Range |
500…1100 hPa |
| Resolution |
Typically 0.084 hPa |
| Accuracy |
±1 hPa (-20…85°C) |
| Long term stability |
±1 hPa/year |
| Internal Measurement (Power) |
Mode |
Battery or power supply level |
| Type |
Voltage |
| SDI-12 input |
Type |
V1.1 compliant |
| Protections |
• Opto-insulation
• Over-current protection by self-replacing PTC fuse
• IEC-61000-4-2 ESD 30 kV (air), 30 kV (contact)
• DATA-SDI12 line protection with gas discharger and digital insulation:
– 1-2 kA surge capability tested with 8/20 us pulse as defined by IEC 61000-4-5
– Conform to ITU-T K12, IEC 1000-4-5
– Insulated Data line up to 4000V peak and 2500V rms per minute |
| RS485 Input/output |
Input numb. |
N.1 |
| Mode |
• Connection to sensor (Modbus RTU Master protocol)
• Connection to SCADA/PLC systems (Modbus RTU Slave protocol) |
| Power supply |
3kVdc insulated |
| RS232 Input/output |
Inputs numb. |
N.2 |
| Mode |
• Connection to Input Extension Module (MDMMA1110)
• Connection to communication devices (modem 3G/4G)
• Connection to SCADA/PLC devices (Modbus RTU – Slave protocol) |
| USB Input/output |
Number |
N.2 |
| Type |
Host, connection type A |
| Mode |
• Connection to pen-driver
• Connection to Wi-Fi antenna (optional) |
| Switched power supply outputs |
Outputs numb. |
N.3 (programmable triggering) |
| Type |
Solid-state V Out = V In |
| Max tension |
1.1 A for each output |
| Mode |
• External sensors power supply
• Communication system power supply
• Alarm
• Timer (date/time or cycles) |
| Protections |
400 W peak pulse at 10/1000 μs waveform
Repetition rate (duty cycle): 0,01% |
| Memory |
Size/Type |
8 GB Flash with UBIFS file system |
| Data memory |
Two levels storage system for greater reliability:
• 7 GB on Flash chip with UBIFS file system
• Up to 32 GB on USB memory stick with FAT32 file system |
| User’s interface |
Display |
57×19 mm. 4 lines x 20 char. Backlit |
| Keyborad |
N.4 buttons |
| Leds |
Diagnostic about:
• Data transmission activity
• System status
• Battery charge status
• Internal Linux computer status (ready/error) |
| Clock |
Accuracy |
1 minute/month accuracy |
| Synchronization |
Automatic from internet time (NTP) |
| ADC |
Resolution |
12 bit oversampled to 14 bit; 16 bit optional |
| Filter |
Noise filtering for 50/60 Hz |
| Data Transmission |
Modem |
External 3G/4G modem (connection to RS232 port) |
| Router |
3G/4G router (connection to Ethernet port) |
| Wifi |
External antenna connected to USB port |
| Linux Computer |
Type |
Linux based internal computer with open and end-user extensible architecture |
| Processor |
32 bit |
| ADC converter |
16 bit |
| Power modes |
• Always ON (always connected to Internet)
• Automatic power ON (awake for data transmission only for best
energy performance) |
| Linux kernel |
V. 2.6.35, Debian Wheezy distribution |
| Ethernet |
Ethernet 10/100 Mbps |
| USB ports |
N.2 USB ports, Host, Type-A connector |
| RAM |
128 MB |
| Watch dog |
Type |
Dual/redundant watch dog system |
| Power supply |
Power supply |
6…30 Vdc |
| Inputs |
Separate inputs from 6…30 Vdc power supply :
• From solar panel (17 Vmin), Max current: 5 A. Recharge voltage: 13,8 V
• From battery/main power supply, Max current: 5 A |
| Peak pulse power capability |
400 W peak pulse at 10/1000 μs waveform, Repetition rate (duty cycle): 0,01% |
| Battery charge |
17 V |
| Protections |
• IEC-61000-4-2 ESD 30 kV (air), 30 kV (contact)
• Over-current protection by self-replacing PTC fuse
• Polarity inversion protection
• Over current protection by input power supply (>33V)
• 400 W peak pulse power capability at 10/1000 s waveform |
| Environmental Limits |
Operating temperature |
-40…80 °C (display off) |
| Operating humidity |
10…99 % RH, not condensing (conformal coating option) |
| Storage temperature |
-40…80 °C |
| Physical parameters |
Weight |
600 g |
| Dimensions |
160x125x50 mm |
| Mounting |
DIN mounting rail 35 mm |
| EMC |
Protections |
EN61326-1 2013, EMC CEI EN 61010-1 2013 |
| RoHS |
Compatibility |
CEI EN 50581_01 2013 |
| Accessories |
|
SVSKA2001 |
Data logger programming hardware kit for firmware update.
Complete with connection cable, user manual and program |
| XLA010 |
USB Memory stick, 8 GB, Industrial grade |
| EDECA1001 |
N.5 50 ohm-resistors kit (1/8 W, 0.1%, 25 ppm)
to convert 4…20 mA -> 200…1000 mV |